User Tools

Site Tools


mri-sequences

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
mri-sequences [2024/02/08 12:20] – [MPRAGE] carlmri-sequences [2024/02/19 14:52] (current) ari
Line 1: Line 1:
 ===== Structural ===== ===== Structural =====
 ==== T1-weighted ==== ==== T1-weighted ====
 +=== MPRAGE ===
 High resolution, T<sub>1</sub>-weighted, structural MRI High resolution, T<sub>1</sub>-weighted, structural MRI
  
Line 15: Line 16:
 | Parallel imaging         | GRAPPA \\ Acceleration factor PE: 2 \\ Reference lines PE: 24 | | Parallel imaging         | GRAPPA \\ Acceleration factor PE: 2 \\ Reference lines PE: 24 |
  
-==== Diffusion MRI ==== +====T2-weighted==== 
-High resolution, T<sub>1</sub>-weighted, structural MRI +=== Turbo Spin Echo (TSE===
- +
-^ Parameter                ^ Value                                                         ^ +
-| Acquisition time         | 4 min 32 s                                                     | +
-| Type                     | 3D (sagittal slices)                                          | +
-| FOV (A-P x L-R x F-H)    | 256 mm x 192 mm x 256 mm                                      | +
-| Matrix                   | 256 x 256 x 192 (rotated!)                                    | +
-| Resolution               | 1 mm isotropic                                                | +
-| TR                       | 2250 ms                                                       | +
-| TI                       | 900 ms                                                        | +
-| TE                       | 2.98 ms                                                       | +
-| Flip angle               | 9 deg                                                         |  +
-| Parallel imaging         | GRAPPA \\ Acceleration factor PE: 2 \\ Reference lines PE: 24 | +
- +
-==== For Incidental Findings ==== +
- +
-=== TSE ===+
 Quick, high (in-plane) resolution, T<sub>2</sub>-weighted, structural MRI (for incidental findings) Quick, high (in-plane) resolution, T<sub>2</sub>-weighted, structural MRI (for incidental findings)
  
Line 49: Line 34:
 | Parallel imaging         | GRAPPA \\ Acceleration factor PE: 2 \\ Reference lines PE: 26 | | Parallel imaging         | GRAPPA \\ Acceleration factor PE: 2 \\ Reference lines PE: 26 |
  
-=== TSE_FLAIR ===+=== TSE FLAIR ===
 High (in-plane) resolution, T<sub>2</sub>-weighted, 'dark-fluid', structural MRI (for incidental findings) High (in-plane) resolution, T<sub>2</sub>-weighted, 'dark-fluid', structural MRI (for incidental findings)
  
Line 65: Line 50:
 | TE                       | 100 ms                                                        | | TE                       | 100 ms                                                        |
 | Flip angle               | 150 deg                                                        | Flip angle               | 150 deg                                                       
 +
 +===== Diffusion MRI =====
 +High resolution, T<sub>1</sub>-weighted, structural MRI
 +
 +^ Parameter                ^ Value                                                         ^
 +| Acquisition time         | 8 min 52 s                                                     |
 +| Type                     | 2D (Axial slices)                                          |
 +| b-value                  | 0, 1000                                     |
 +| Number of directions     | 64 (256 possible with a larger TA)                                        |
 +| FOV                      | 192 mm x 192 mm                                       |
 +| Matrix                   | 96 x 96                                     |
 +| Resolution               | 2 mm isotropic                                                |
 +| TR                       | 7800 ms                                                       |
 +| TE                       | 90 ms                                                       |
 +| Flip angle                                                                        | 
 +| Parallel imaging         | GRAPPA \\ Acceleration factor PE: 2 \\ Reference lines PE: 24 |
 +
  
 ===== BOLD fMRI ===== ===== BOLD fMRI =====
mri-sequences.1707394802.txt.gz · Last modified: 2024/02/08 12:20 by carl

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki